Problem: IoTAS was approached by a manufacturer who was looking to launch a product in Puerto Rico. The product supports CAT M1 and would be used under dynamic conditions. However, after the customers initial investigation they found that the performance of the CAT M1 device was not consistent. On further inspection there appeared to be a few areas where the device had completely lost coverage. The manufacturer had an alternative CAT 1 device which may be more suitable for this location. IoTAS were asked to investigate the coverage available and compare the difference in performance between the CAT M1 device and CAT 1 device.
Solution: Initially IoTAS reviewed the coverage maps available to verify that there should be suitable coverage for CAT M1 and CAT 1. IoTAS then arranged for an engineer to complete field trial testing using a trace tool to capture the performance of the CAT M1 device and CAT 1 device. A long drive route was mapped to travel between populated destinations in Puerto Rico to verify the performance of both devices. A report was generated detailing the coverage observed during testing and any areas where the device lost coverage, comparing the CAT M1 device to the CAT 1 device.
Result: IoTAS supplied a fully comprehensive test report including a detailed analysis of the drive route completed, displaying where connectivity differed between both the CAT M1 and CAT 1 products. All trace logs were shared with the customer for further analysis, to identify if there are any underlying problems with the products software. From the in-depth analysis supplied by IoTAS the customer was able to be select an appropriate product for launching in the Puerto Rican market.