Evaluate Performance of CAT 1bis with CAT 1 on the Live Network
Problem: IoTAS was approached by a manufacturer to perform live network field testing of CAT 1bis and CAT 1 modems. The objective was to compare the performance of both technologies at the edge of coverage to show the real world difference of RF sensitivity.
Solution: IoTAS identified a suitable test location (rural location with good signal quality and poor signal strength) and created a suitable test plan which measured time to attach, ping response time and data throughput speed. Each test was run several times, at different RSRP levels starting from -130dBm (and then reduced the RSRP by about 2dB per iteration until similar performance was seen by all modems).
Result: IoTAS generated scripts to post process the log files and make graphs to easily seen the difference of performance to include in a detailed test report. The results showed CAT 1 has roughly a +3dB advantage over CAT 1bis in a cell edge scenario.
For more information, please call IoTAS on +44 1223 810010